![Worcester GR2300iW C Installation And Maintenance Instructions Manual Download Page 88](http://html.mh-extra.com/html/worcester/gr2300iw-c/gr2300iw-c_installation-and-maintenance-instructions-manual_996431088.webp)
Technical Specifications/Logs
Greenstar 2000 – 6 721 820 552 (2021/02)
88
Table 39 Technical data Greenstar 2000 NG
General data
Expansion vessel capacity
l
6
6
6
Expansion vessel pre-charge pressure
bar
0.75
0.75
0.75
Appliance protection rating
4)
IP
X4D
X4D
X4D
Permissible ambient temperature short-term/long-term
°C
0-50/40
0-50/40
0-50/40
Nominal capacity of the appliance
l
7
7
7
Total package weight
kg
40
40
40
Total appliance weight (excluding packaging)
kg
36
36
36
Lift weight (without front panel)
kg
33.4
33.4
33.4
SEDBUK 2009
%
89.1
89.1
89.1
1) For minimum and maximum permissable pressure refer to “Gas pressure within the system”, section 6.6.
2) The Gas Rate provided assumes the accepted NG averaged calorific value of 34-9 MJ/m
3
net.
3) Appliances are fitted with a flow regulator set to achieve a 35°C temperature rise. A 40°C temperature rise is possible at lower flow rates.
4) Protection rating may change depending on the control unit/s used on this appliance.
Greenstar 2000
GR2300iW C
Description
Unit
25kW NG
Low NOx 25kW/30kW
30kW NG