Maintenance & Alignment
EG250 Safety Devices Inspection (CE version only)
6
6-23
EGdoc022715
Maintenance & Alignment
Push the E-STOP button located on the edger housing. The motor should stop. It should not be
possible to restart the motor until the E-STOP is released.
3. Cover Safety Switch Circuit Inspection
Start the main motor;
Open the cover ;
The main motor should stop;
Try to start the motor using the START button. It should not be possible to start the motor.
Close the cover;
The motor should remain turned off.
4. Sawdust Hopper Safety Switch Circuit Inspection
Start the main motor;
Open the sawdust hopper cover;
The main motor should stop;
Try to start the motor using the START button. It should not be possible to start the motor.