OPERATION
Additional Fixed Blade Option
3
3-22
EGdoc022715
Operation
- for 3 blades 65 mm (2.56")
- for 4 blades 40 mm (1.57")
- for 5 blades 25 mm (1")
Additional Fixed Blade Option
The edger can be equipped with an additional fixed blade (optional equipment).
NOTE:
It is necessary to readjust the movable blade limit switch after mounting the additional fixed
blade (or blades). To do that, measure the distance from the left edge of the fixed blade arbor to the
left edge of the last added blade (see the figure below). Loosen the mounting screws and move the
limit switch left, the measured distance.
WARNING!
If the limit switch is not readjusted after mounting
additional blades, damage to the machine equipment may occur.
FIG. 3-19
100mm
7.873"
100mm
200mm
3.937"
3.937"