wolfappliance.com/specs
ELECTRICAL REQUIREMENTS
Wolf cooktop wall and island hoods require a separate,
grounded 120 V AC, 60 Hz power supply. The service
should have its own 15 amp circuit breaker.
Planning Information
Wolf cooktop ventilation hoods are recommended for use
with Wolf induction, electric and gas cooktops and inte-
grated modules. These hoods have a telescopic chimney
flue that allows you to reach a ceiling height of 8' (2.4 m)
to 9' (2.7 m). A flue extension to accommodate 10' (3 m)
ceilings is available through your authorized Wolf dealer.
Wall and island hoods are shipped without the blower
assembly. Internal, in-line and remote blowers are
available through your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of our
website, wolfappliance.com.
The blower will vary in size and is dictated by the cooking
unit, the volume of air that needs to be moved and the
length of the duct run. Refer to ventilation recommenda-
tions on pages 109–110. These hoods have an 8" (203)
round duct with vertical discharge.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.