Wolf Gas Cooktops
41
wolfappliance.com/specs
ELECTRICAL AND GAS REQUIREMENTS
Gas cooktops require a separate, grounded 120 V AC, 60
Hz power supply. The service should have its own 15 amp
circuit breaker, and a grounded 3-prong receptacle should
be located within reach of the 6' (1.8 m) power cord.
A gas supply line of
3
/
4
" rigid pipe must be provided to the
cooktop. If local codes permit, a certified, 3' (.9 m) long,
1
/
2
" or
3
/
4
" ID flexible metal appliance connector is recom-
mended to connect the cooktop to the gas supply line.
Wolf gas cooktops are designed to operate on natural gas
at 5" (12.5 mb) WC pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure is 7" (17.5 mb) WC
for natural gas and 11" (27.4 mb) WC for LP gas. The
maximum gas supply pressure to the regulator should
never exceed 14" (34.9 mb) WC, .5 psi (3.5 kPa).
Wolf natural gas cooktops will function up to an altitude
of 10,250' (3124 m) without any adjustment. LP gas
cooktops will function up to 8,600' (2621 m) without
adjustment. If the installation exceeds these elevations,
contact your authorized Wolf dealer for a high altitude
conversion kit.
Planning Information
For ease of installation, Wolf recommends using 33" (838)
wide cabinets with 30" (762) gas cooktops and 39" (991)
cabinets with 36" (914) cooktops.
Burner Rating
Btu
(kW)
Btu
(kW)
15"
(381)
GAS COOKTOP
HIGH
SIMMER
Medium
12,000
(3.5)
800
(.2)
Small
9,200
(2.7)
300
(.1)
30"
(762)
GAS COOKTOP
HIGH
SIMMER
Large
15,000
(4.4)
800
(.2)
Medium
12,000
(3.5)
800
(.2)
(2) Small
9,200
(2.7)
300
(.1)
36"
(914)
GAS COOKTOP
HIGH
SIMMER
Large
15,000
(4.4)
800
(.2)
Medium
12,000
(3.5)
800
(.2)
(3) Small
9,200
(2.7)
300
(.1)