Compliance
All components comply with UL, CE, and RoHS specifications.
The AMP1-8-M meets FCC Part 15 compliance.
Specifications
Table 4-1: Specifications
Specification
Values / Domains
Power requirements
100 V to 240 V AC ± 10%, 50/60Hz
Power consumption
60 Watts
Dimensions (H x W x D)
1.75” x 19” x 4.25”
(44mm x 483mm x 107mm)
Weight
5 lbs. (2.3 kg)
Space Required
1 RU (rack unit)
Supplied Accessories
AC Power Cord (North America)
Display Type
TFT LCD
Number of Displays
2
Screen Size
2.4” diagonal per screen
Screen Resolution
320 x 240
Inputs
SDI: 2 3G/HD/SD-SDI on BNC
Outputs
SDI: 2 regenerated on BNC
SDI: 1 selected reclocked on BNC
Analog: 2 balanced channels on XLR-
M
Level Meters
166 segments
Level Meter Scales
Selectable:
AES; VU; Ex. VU; BBC; EBU;
Nordic; DIN
Level Meter Characteristics
Selectable:
Meter thresholds
Reference
Segment Colors
Ballistics
Peak Acoustic Output
90dB SPL (@ 2 feet)