Bedienungsanleitung Steuerung S4_2006_09_25-neu.doc
Page 27 / 83
© wodtke GmbH Tübingen. All rights reserved. Subject to change without notice.
Month of issue xx/2007
Art. No. 950 281
6 Menu Level / Sampling of Functional Values
To sample functional values press the “Menu” key. Whenever you
jump to the menu level the screen shown on the right appears
indicating the installed software (for ex. S4 002). Use the +/- keys
to display the other menu screens.
To quit the menu level and enter the operating level press the
“Menu” key again. If 60 seconds elapse without a key being pressed
the system will automatically return to the operating level.
It is not possible to make changes to the appliance from the menu
level. Exception: The only exception to this is the I/O key, with which
you can switch the appliance on and off even when working at the
menu level. The I/O key is also active at the menu level.
Important Note:
Whenever any of the codes shown in the following table appear on the display this
means you are at the menu level. It is not possible to operate the appliance from this
level (except switch it “ON/OFF” via the I/O key).
Menu screen
Explanation
Desired value
Remarks
S4 001
or S4 002
or S4 003 etc.
Currently
installed
software version
---
Indicates which software is on the
circuit board. It does not refer to
the programme version, which is
what determines power capacity
etc.
Z on or Z OFF
Ignition
On
=
first
10
minutes after Start,
otherwise Off
S 0.0 to S 4.5
Working
time
of feed
screw
in
seconds
at
maximum clock frequency
4.5 s.
0.7 – 2.6 (6 kW
stoves)
0.7 – 3.5 (8 kW
stoves)
0.7 – 4.5 (10 kW
stoves)
U
Performance
(expressed
as voltage) of flue gas fan
in % (= control value as a
function of standard value
L)
Min.
value
for
preheating
programme U
≥
42; min. value for
heating
programme U
≥
24
Control value depends on set
performance, chimney draught and
soiling of appliance.
L
Air throughput at air flow
sensor (= standard value)
Standard value may fluctuate due
to chimney draught and especially
soiling of appliance.
TP
Temperature
at
pellet
chute
TP < 200 °C (only
6
kW
Airplus
appliances)
TP < 170 °C (all
other appliances)
Temperatures greater than the
desired value TP trigger an error
shutdown.
TL
Temperature at air flow
sensor
TL < 85 °C
Measured
at
suction
pipe;
temperatures
greater
than
the
desired value TL trigger an error
shutdown.
TR
Temperature at flue gas
fan
TR min
≥
49 °C
TR max < 200 °C
( 6 K hysteresis)
Sampling 21 minutes after Start;
temperatures lower than desired
value TR trigger an error shutdown,
while
overtemperature
triggers
internal
modulation
(“H.M”
appears).
w
o
d
tk
e
S4
002