AHD Speed Dome Camera Introduction Manual
8
▌▌
DIP Switch Setup
Before you install the camera, you should set the DIP switches to configure the camera ID,
communication baud rate.
►
Camera ID Setup
ID number of camera is set using binary number. The example
is shown below.
PIN
1
2
3
4
5
6
7
8
ID Value
1
2
4
8
16
32
64
128
OSD menu setup
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ex ) ID=5
ex ) ID=10
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
The range of ID is 1~255. Factory default of Camera ID is 1.
If you want to control a certain camera, you must match the
camera ID with Cam ID setting of DVR or Controller.
When DIP SW set all off the speed dome can change the ID
address and baud rate via OSD menu.
Camera ID Communication Baud Rate
PIN
1
2
3
4
5
6
7
8
9
10
FUNC.
A0
A1
A2
A3
A4
A5
A6
A7
Baud Rate
ON
1
2
4
8
16
32
64
128
Refer to
the Manual
OFF
0
0
0
0
0
0
0
0