AHD Speed Dome Camera Introduction Manual
9
►
Communication Baud Rate Setup
Select the appropriate Baud Rate with DIP
switch combination.
Switch State
Baud Rate
P9
P10
OFF
OFF
default 2400 bps
ON
OFF
2400 bps
OFF
ON
4800 bps
ON
ON
9600 bps
If you want to control using DVR or P/T
controller, their protocol must be identical to
camera. Otherwise, you can not control the
camera.
If you changed camera protocol by changing DIP
S/W, the change will be effective after you reboot
the camera.
Factory default of baud rate is 2400 bps. You
can change it in OSD menu.
Speed dome will detect the Pelco-D or
Pelco-P automatically in the Present
conditions.