background image

13

Installation instructions Primor

7 Installation input unit Primor FS

7.1 Input unit Primor FS

7.1.1 Dimensions Primor FS

7.2 Mounting input unit

7.2.1 Drill pattern Primor FS

Fixing position for screws M5

Ø 95

40

46

23

5,1

5

Opening for cable:
Drill-hole min. Ø 8 mm/max. Ø 11,4 mm for connection 
cable has to be drilled into the safe door

• From the front 2 threaded holes M5 with sufficient depth and 1 through-hole (opening for cable) have to be drilled into 

the safe door.

• Fix the input unit with the enclosed cylinder screws M5 from the front.

7.2.2 Cable guidance Primor FS

7.2.3 Plug position Primor FS

Bottom of case

Connection cable lock

Battery clip

Folding unit

Fixing screw

Battery

Lock

• Lead connection cable of the lock and connection cable 

of the battery behind the bottom of the case of the input unit.

Summary of Contents for Primor 100

Page 1: ..._________________________________________________ 11 7 Installation input unit Primor FS____________________________________________________ 13 8 Installation lock_________________________________________________________________ 14 9 Mounting lock Primor 100________________________________________________________ 15 10 Mounting lock Primor 1000______________________________________________________...

Page 2: ...struction We point out that this installation instruction is part of the VdS certification and non compliance leads to the loss of this certification By opening the lock cover warranty of the manufacturer will be void Take care that the input unit or the lock and the cables should not be damaged 2 System overview Primor RE Primor FE Primor RO Primor FL Primor FS Primor 100 Primor 1000 Primor 2000 ...

Page 3: ...Black covering cap Red covering cap Cylinder screws M5 x 14 Cylinder screws M5 x 18 O ring Battery compartment cover Lever input unit 3 3 Axis length calculation input unit Primor RE 3 3 1 In connection with Primor 100 3 3 2 Panel hole spindle A L Spindle Debur the ends A L A L Türlochbohrung Türlochbohrung mind ø9 max ø10 6 mind ø10 6 max ø11 4 min Ø 10 6 mm max Ø 11 4 mm L A 35 mm tolerance 2 mm...

Page 4: ...d 1 through hole opening for cable Spindle have to be drilled into the safe door 3 4 2 Cable guidance Primor RE 3 4 3 Cable guidance Plug position Primor RE Spindle O ring Lock Lead the connection cable through the Spindle Push the cable and the O ring in the direction of the arrow until the inset Connect the plug of the cable with the plug on the circuit board Attention Don t put the connection c...

Page 5: ...allation input unit Primor FE 4 1 Input unit Primor FE 4 1 1 Dimensions Primor FE 52 5 83 11 5 156 26 4 2 Installation overview 4 2 1 Input unit Primor FE Axe profile M5 x 14 Cylinder screw M5 x 18 Black covering cap Battery compartment cover ...

Page 6: ...with sufficient thread depth and 1 through hole opening for cable Spindle have to be drilled into the safe door 4 3 2 Plug position Primor FE Lock Connect the plug of the cable with the plug on the circuit board Attention Don t put the connection cable under tensile stress Fix the input unit from the front with the enclosed cylinder screws M5 Install covering caps and battery compartment cover see...

Page 7: ...Fixing ring for input unit 4 Cylinder screws M4 x 10 Spindle for turnable input unit Input unit Connection cable 5 3 Panel hole Primor RO turnable 5 3 1 Spindle square 5 3 2 Spindle round Türlochbohrung Türlochbohrung mind ø9 max ø10 6 mind ø10 6 max ø11 4 min Ø 10 6 mm max Ø 11 4 mm Türlochbohrung Türlochbohrung mind ø9 max ø10 6 mind ø10 6 max ø11 4 min Ø 9 mm max Ø 11 4 mm ...

Page 8: ... the ends L A 43mm Toleranz 4mm A L L A 43mm Toleranz 4mm A L L A 43mm Toleranz 4mm A L L A 28 mm tolerance 4 mm L A 43 mm tolerance 4 mm 5 4 3 In connection with boltwork L 15mm A X A 15 X Achse in axialer Richtung gegen verschieben sichern L L 15mm A X A 15 X Achse in axialer Richtung gegen verschieben sichern L Secure the axis against shifting in axial direction Spindle Debur the ends L X A 15 ...

Page 9: ...threaded holes Primor RO 78 78 4 3 4 3 41 5 41 5 4 4 3 78 78 4 3 4 3 41 5 41 5 4 4 3 Opening for cable 4 x fixing positions for screws M4 oprionally Ø 41 5 mm or Ø 78 mm Hole center congruent with middle axis of nut of the electronic lock From the front 4 threaded holes M4 with sufficient depth thread and 1 through hole opening for cable Spindle have to be drilled into the safe door From the front...

Page 10: ... the input unit Fit input unit of approx 20 see 5 5 2 adjusting and insert grub screw M3 x 6 or arrest pin Fit input unit of approx 20 see 5 5 2 adjusting and insert clip 5 5 5 Cable guidance Primor RO drehbar 5 5 6 Plug position Primor RO Spindle Lock Lead connection cable through the input unit Insert the Spindle into the input unit from behind Lead connection cable through the input unit and co...

Page 11: ...FL fixing on the inside 6 1 2 Input unit Primor FL fixing on the front 6 1 3 Dimensions Primor FL Emergency 6 2 Mounting input unit 6 2 1 Drill pattern Primor FL Fixing position Fixing on the inside Through hole for screws M5 Fixing on the front Thread M3 Ø 92 Notbestromung emergency power supply 12 82 Opening for cable Drill hole min Ø 8 mm max Ø 11 4 mm in the safe door for connection cable Fixi...

Page 12: ...ent has to be fixed to the inside of the door It is recommended to fix it in a way that it is accessible without unscrewing the interior of the door To avoid a short circuit independent discharge no connection between the inputs of the battery sliding compartment and other components may occur 6 3 5 Plug position Primor FL Lock Battery The two 4 pin plug connection must be accessible at all times ...

Page 13: ...o be drilled into the safe door From the front 2 threaded holes M5 with sufficient depth and 1 through hole opening for cable have to be drilled into the safe door Fix the input unit with the enclosed cylinder screws M5 from the front 7 2 2 Cable guidance Primor FS 7 2 3 Plug position Primor FS Bottom of case Connection cable lock Battery clip Folding unit Fixing screw Battery Lock Lead connection...

Page 14: ...losures it is re commended to carry out a security and functional test of the electronic lock For safety reasons it is not allowed to locate the electronic lock in the area where openings are except Primor 100 2000 The electronic lock has to be protected against external attacks It is recommended to protect all security relevant components of the high security lock against tempering even when the ...

Page 15: ...tch 9 1 2 Option lock cover screwed 25 110 78 112 5 142 66 5 41 Ø 6 5 78 110 142 9 1 3 Option lock cover welded without anti drilling plate 9 1 4 Option lock cover welded with anti drilling plate 25 Ø 6 5 78 110 78 112 5 142 25 66 5 41 Ø 6 5 78 110 78 112 5 142 If the lock is mounted without its lock case further installation guidelines have to be considered Non observance leads to loss of VdS cer...

Page 16: ...e electronic lock Lead the connection cable of the input unit through the square nut of the lock Attention Don t put the connection cable under tensile stress _Afterwards the lock has to be stuck onto the spindle of the input unit that is already inside the door The electronic lock has to be fixed with the screws included in the scope of delivery or cylinder screws M6 or 1 4 at least property clas...

Page 17: ...ng seams on the corners of he lock case to the inside of the safe door Make sure that the lock cover possibly with hardened manganese steel plate is fixed tightly onto the door Welding distortion has to be avoided Lead the connection cable of the input unit through the square nut of the lock Attention Don t put the connection cable under tensile stress _The lock then has to be plugged onto the Spi...

Page 18: ...s with depth min 5 mm for fixing the key lock have to be drilled into the safe door The electronic lock has to be fixed with the screws included in the scope of delivery or cylinder screws M6 or 1 4 at least property class 8 8 The screw length should be 30 mm or longer so that a minimum thread length of 5 mm is achieved Primor 2000 Lead connection cable through the lock and adjust the electronic l...

Page 19: ...3010 short unlocking lever with mechanical emergency lock 60 7 12 mm Platzbedarf required space 66 5 9 1 41 25 4 Ø 7 Hub stroke 12 25 5 66 5 13 Ø 7 150 41 6 8 34 15 M 4 10 6 Mechanical emergency lock N 1821 Primor 3010 Installation example If the emergency lock N 1821 is not used the electronic lock Primor 3011 has to be used 11 2 2 Einbaumaße Primor 3011 short unlocking lever with mechanical emer...

Page 20: ...1 2 4 Operating notes Primor 3010 3011 emergency lock The lock may only be operated with the according keys The insertion and opening attempts with other keys can lead to internal damage Never use force 11 2 5 Operating the lock Index Index Insert key so that the marking on the key head is pointing towards the lock s bolt _When using right hand locks turning axis towards the right the key has to b...

Page 21: ...then fix them permanently Plug the connection cables of the signal box optional into the position signal box on the lock For further installation notes please see the separate installation instruction PrimorSignal PrimorSignalPlus 13 External power supply The locks Primor 1000 2000 3000 3010 3011 can be power supplied externally by PrimorSignal plus When using mains adapter as primary power supply...

Page 22: ... turn the boltwork s handle into the opening position The bolt swings in has to happen easily The lock is opened Turn the boltwork s handle into the locking position The swing bolt automatically folds out and locks The lock is closed Primor 3000 3010 3011 The lock s bolt opens automatically has to happen easily The lock is opened Turn the handle within 3 seconds into opening position Turn the hand...

Page 23: ...23 Installation instructions Primor ...

Page 24: ...24 Installation instructions Primor ...