manualshive.com logo in svg
background image

30.08.2017

 

3b 

4b 

4

а

 

3

а

 

 

 

SHERIFF-1 premium 

ELECTROMECHANICAL LOCK 

 

OPERATING MANUAL   

TU 3428 – 003 – 80210527 – 14 

PATENT OF INVENTION 

238261

 

 
 

1. 

APPLICATION 

Electromechanical lock "Sheriff-1 premium" is designed for locking hinged doors, opening inward and outward, with a possibility of 

remote  opening  them  with  the  controllers  of  access  control  systems,  audio  and  video  door  phones,  code  access  panels.  The  lock 
design and the method of installation allow you to place the lock indoor and outdoor of protected premises. 
 
2. 

OPERATING CONDITIONS 

Climatic operating conditions: 

- ambient air temperature: from -40 to +50°

С

- relative air humidity not more than 95% at 35°

С

 and with lower temperatures without condensation and frost formation; 

- installing  indoors  in any type of doors; 
- resistance to the environmental exposure complies with GOST 15150-69:UHL2. 
 
3. 

TECHNICAL SPECIFICATIONS 

The  lock  "Sheriff-1  premium"  is  produced  in  the  normally  open  type  (or  fail-safe),  the  lock  remains  open  when  the  voltage 

supply is off and is closed when the voltage supply is on. The lock has two integrated sensors: of the door position and of the lock 
status. 

Integrated  sensor  of  the  door  position  consists  of  the  reed  switch  placed  on  the  lock  case  and  the  magnet  placed  on  the 

movable bush of the lock and moved by the deadbolt. The reed switch contacts are open when the door is open (the deadbolt is out 
of the lock) and are closed when the door is closed (the deadbolt abuts to the lock).  

Integrated  sensor  of  the  lock  status  consists  of  the  reed  switch  fixed  to  the  electromagnet  coil  of  the  lock.  The  reed  switch 

contacts are open when the voltage supply is off, and are closed when the current flows on the coil. 

Thus, if insert consistently both sensors in the circuit, then the circuit will be closed only when the deadbolt is in the lock (the 

door is closed) and the lock draws current (the status is closed). 
 

 
 

 
             * Note:  1. The lock in this delivery set (see Para. 4) is designed to be mounted on the door with the door stop width more than 25,5mm 

and  the  door  leaf  thickness  25-45mm.  To  mount  the  lock  on  the  door  with  other  dimensions  needed  to  use  the  Additional 
fixation set (see the Operating Manual). 

2. The length of the bolt 

М

8

х

35 for 

deadbolt

 fixing (without head) should be less than the thickness of the door on 3-7mm 

(shorten the bolt if needed). 

 
 

4. 

DELIVERY SET 

1 – Lock  

 

                           1 pc. 

2 – Bracket                          

 

1 pc. 

3

а

 – Binder bolt M4 for lock fixing     

2 pcs. 

3

б

 – Screw 

М

4   

 

 

2 pcs. 

4

а

 – Screw 4

х

30 for bracket fixing               2 pcs. 

4

б

 – Countersunk screw 4

х

30 for bracket  

fixing                              

 

 

2 pcs. 

5 – Deadbolt assembly 

 

 

1 pc. 

6 – Bolt 

М

8

х

35 for deadbolt fixing            

1 pc. 

7 – Template for brackets fixing                

1 pc. 

8 – Marking tool                               

1 pc. 

9 – Operating manual 

                           1 pc. 

10 – Additional fixation set                         

1 pc. 

 
Check completeness of the delivery set while purchasing.  

Subsequently, the company-manufacturer does not accept any claims over completeness of the delivery set. 

The maximum current of the reed 
switches, A, not more than 

0.5 

The maximum voltage of the reed 
switches, V, not more than 

 
36 

Product type 

normally open 

Door leaf thickness, mm 

 
25-70* 

Possible adjustments 

of the locking bolt length;  
automatic   deadbolt   
alignment in the lock 
opening 

Holding force, kg, no less than 

400  

DC voltage supply, V   

 
10 - 15   

Current consumption (12V), m

А

, not 

more than 

 
105  

Lock weight, kg, not more than 

0.3 

Dimensions  (W

х

H

х

L), mm 

 
34

х

30

х

130 

Four wire cable and power cable 
length, m 

 
0.3 

Reliability of operation cycles, not 
less than 

 
400, 000 

Color:

 

white,

 

silver,

 

brown 

Production date: 

 

Содержание SHERIFF-1 premium

Страница 1: ...e voltage supply is off and are closed when the current flows on the coil Thus if insert consistently both sensors in the circuit then the circuit will be closed only when the deadbolt is in the lock the door is closed and the lock draws current the status is closed Note 1 The lock in this delivery set see Para 4 is designed to be mounted on the door with the door stop width more than 25 5mm and t...

Страница 2: ...ted premises is closed the deadbolt should be inserted in the lock to the stop the door is in a tension state i e there is an external effort applied for opening handle is pulled the necessary clearance gap of the door is 2 5 3mm may not closed see Para 6 this lock to restrict access to premises and the place of company based on the characteristics of the design and the level of premise accountabi...

Страница 3: ...thin the permissible clear interrupting the power supply and for it is usually used a controller contro done according to the technical data sheet power of the lock is supplied by the voltage from 10 to 15 V of the direct current When the power supply is on the lock is closed when it is off the lock is open positive pole of the power supply negative pole of the power supply does not provide operab...

Страница 4: ...l Department Within the warranty period Engineering Technical Center PROMIX LLC undertakes to repair the defective product free of charge The shipping cost to the place of repair and back shall be borne by the Buyer The warranty shall not cover defects or damages resulting from improper maintenance by the Buyer using the lock in conditions that do not conform to the operating requirements mechanic...

Страница 5: ... 2 pcs Fix with screws angular brackets and the lock bracket Fasten the brackets to the lock Fix the lock to the door frame Plug the lock mark and mount the deadbolt to the door in accordance with the Operating Manual In all versions of lock mounting it is necessary that the distance between the door and the lock case will be from 10 to 13 5mm The length of the locking bolt established for the dis...

Страница 6: ...ter 4 2 4 7mm at specified locations of the angular bracket see Table 2 Swap and turn over the lock brackets during the installation Table 2 А мм 17 0 20 5 20 5 23 0 23 0 25 5 Holes drilling location 25 5mm and more The lock fixing carried out in accordance with the Operating Manual LOCK Door frame LOCK LOCK Door frame DOOR DOOR DOOR Locations of fixing to the door frame Locations of fixing to the...