Installation instructions Primor
9.3 Mounting lock Primor 100 - lock cover welded
9.3.1 Dimensions lock 100 - lock cover welded
(without anti-drilling plate)
9.3.2 Dimensions lock Primor 100 - lock cover welded
(with anti-drilling plate)
Hub/Stroke 12
25
142
15
25,4
Ø
4,5
7
102,1
9
70
27
78
58
110
115
8
60,7
Platzbedarf für Riegelhub /
Required space for bolt throw
2,5
22
13
9
3
Hub/Stroke 12
25
142
15
25,4
Ø
4,5
7
78
27
112,5
115
58
8
102
Platzbedarf für Riegelhub /
Required space for bolt throw
2,5
10
23
14
3
• Before welding the lock cover, the lock case has to be removed.
• When positioning keep the middle of the Spindle congruent with the input unit RO/RE.
• Weld the lock case (if so with hardened manganese steel plate) with 4 welding seams, length 15-20 mm (position of the
welding seams on the corners of he lock case) to the inside of the safe door. Make sure that the lock cover (possibly with
hardened manganese steel plate) is fixed tightly onto the door.
• Welding distortion has to be avoided.
• Lead the connection cable of the input unit through the square nut of the lock.
Attention: Don’t put the connection cable under tensile stress.
• The lock then has to be plugged onto the Spindle of the input unit, which is already in the safe door.
• Optional: Insert extension latches into the guiding pins at the back of the lock in the right direction and pull up the extension
latch that closes to the top.
• The electronic lock has to be fixed with the 4 enclosed flat-headed screws M6 x 12 with the designated drillings of the lock
case in order that permanent foothold is guaranteed
• Turn the screws with
a maximum turning force of 3.5 – 5 Nm.
• After mounting the bolt
/extension latch
must not be under tension.
• After the installation the lock’s bolt may not be load
ed.