background image

MiniTech 

User Instructions 

Summary of Contents for MiniTech

Page 1: ...MiniTech User Instructions...

Page 2: ...10 LOCK SETUP 10 SETUP WITH DALLAS KEY 10 SETUP WITH PC 11 OPENING WITH DYNAMIC CODES 11 BLOCK AND UNBLOCK THE LOCK 12 TEST MODE 12 KEYPAD LANGUAGE 13 AUDIT 13 EVENTS CHECK ON LCD 13 DOWNLOAD THE AUD...

Page 3: ...DD NEW VALUES 17 OPENING PERIODS ADD NEW VALUES 18 OPENING PERIODS VERIFY OR DELETE VALUES 19 AUDIT 19 DOWNLOAD THE AUDIT ON A DALLAS KEY 19 EVENTS CHECK ON LCD 19 CHANGE MASTER CODE 20 MANAGER MANAGE...

Page 4: ...ies the correct and complete operation of the product Use only DURACELL 9 Volt Alkaline batteries or battery holders with DURACELL 1 5 Volt Alkaline batteries Alternatively it is possible to use a 12V...

Page 5: ...ress To confirm an operation press To leave a menu or come back to the main menu scroll the functions until EXIT and press OK To enter a code plus Dallas key if set enter the code digits and insert th...

Page 6: ...an its beginning validity time LCD shows WRONG DYNAMIC CODE To open or access the menu in dual mode if set enter the first code LCD shows Then enter the second code ENTER 2 CODE X X X X X X X X Shortc...

Page 7: ...uct an opening can be performed by entering sigle users codes no dual mode and without time delay Thus the user manual must be adapted according the configuration selected It is strongly recommended t...

Page 8: ...cription Silent alarm With this function enabled enter an opening code increasing or decreasing by one number the last code digit ex 03 030304 or 03 030302 instead of 03 030303 the lock opens and simu...

Page 9: ...de Press to scroll users list or enter user ID 02 03 04 05 06 x _ _ user installed _ user deleted X user disabled Override users 50 59 can be only installed when the lock is open Press If the user is...

Page 10: ...codes Power up the keypad and insert the Dallas dynamic key in the Dallas reader Alternatively press and hold to enter the dynamic user PIN optional LCD shows DYNAMIC USER X X X X Enter the dynamic u...

Page 11: ...confirm LCD shows LOCK BLOCKED To unblock the lock press and hold LCD shows UNBLOCK SYSTEM X X X X X X X X Enter the requested code LCD shows OPERATION DONE Depending by the lock setup you may be req...

Page 12: ...ough an USB interface Direct PC connection allows to download all 5500 events using an USB interface and a specific software For further information refer to the user manual IU_DMT_Audit_00_XX or cont...

Page 13: ...Manager code LCD shows ENTER DALLAS Wait for few seconds or press LCD shows PC LINK SCROLL EVENTS Press LCD shows PC LINK Start the download using the software DMT Audit or press to exit If the stati...

Page 14: ...k must be open System Info Power up the keypad Press and hold LCD shows the keypad firmware version MiniTech v 1 00 21 02 12 Press and hold to see lock info Dynamic keypad ID and DyamaWeb software lic...

Page 15: ...ings for time lock closing periods opening periods only if current time and date values are included in an opening period Enter the Master menu Press until LCD shows TIME LOCK SETTING Weekly time lock...

Page 16: ...shows WEEKLY TIME LOCK SETTING Press LCD shows ADD NEW VALUES Press LCD shows VERIFY OR DELETE VALUES Press LCD shows the values for the first day hh mm FRI hh mm Press to scroll all the schedules lis...

Page 17: ...DELETE VALUES Press to check the first closing period scheduled GG MM AAhh mm GG MM AA hh mm Press to scroll all the scheduled closing periods Press to delete the scheduled closing periods DELETE VAL...

Page 18: ...UES Press LCD shows VERIFY OR DELETE VALUES Press LCD shows the first opening period GG MM AA hh mm GG MM AA hh mm Press to scroll all the scheduled opening periods Press to delete LCD shows DELETE VA...

Page 19: ...enter Master menu Press until the LCD shows MANAGER MANAGEMENT Press LCD shows MANAGER V installed _ deleted X disabled Press If the Manager is not installed LCD shows 01 INSTALL Press to confirm Then...

Page 20: ...E STATIC CODES Press LCD shows OPERATION IN PROGRESS Once terminated LCD shows DYNAMIC CODES ACTIVE To re install the static codes only for Master and Manager use the dynamic user REMOVAL Later it is...

Reviews: