16
Installation instructions Primor
9.2 Mounting lock Primor 100 - Schlossdecke anschraubbar
9.2.1 Dimensions lock Primor 100 - lock cover screwed
7
Hub/Stroke 12
9,1
66,5
102
25
142
41
15
25,4
Ø
4,5
Ø 6,5
60,7
110
58
27
115
8
Platzbedarf für Riegelhub /
Required space for bolt throw
2,5
22
13
9
3
• 4 threaded holes M6 or 1/4" with depth min. 5 mm for fixing the key lock have to be drilled into the safe door.
• Optional: Insert extension latches into the guiding pins at the back of the lock in the right direction and pull up the extension
latch that closes to the top.
• The lock case is put on top of the electronic lock.
• Lead the connection cable of the input unit through the square nut of the lock.
Attention: Don’t put the connection cable under tensile stress.
• Afterwards the lock has to be stuck onto the spindle of the input unit that is already inside the door.
• The electronic lock has to be fixed with the screws included in the scope of delivery or cylinder screws M6 or 1/4" (at least
property class 8.8). The screw length should be 30 mm or longer so that a minimum thread length of 5 mm is achieved.
• Independent loosening of the screws has to be avoided. Recommendation: put lock washers underneath the screw’s head.
• Turn the screws with a maximum turning force of 3.5 – 5 Nm.
• After mounting the bolt
/extension latch
must not be under tension.
• After the installation the lock’s bolt may not be load
ed.