TP
+
ATEX
Appendix
Revision: 04
2022-D020259
en-47
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see Chapter 10.4 "Specifications for startup and
Lubrication
–
High-performance lubricating grease based on
mineral oil
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
38
44.5
34.6
25.5
25.5
20.6
48
58.8
41.9
32.9
32.9
28.0
55
61.5
51.5
42.3
42.3
37.3
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-32: TP
+
110 MF, 1–stage: Technical data for use in potentially explosive atmospheres
Technical data for TP
+
110 MF, 2-stage, i = 16 – 35
Clam-
ping
hub Ø
[mm]
Ratio i
16
20
21
25
28
31
32
35
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
1280 1280 1120 1280 1280 1280 1280 1280
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
686
686
595
735
735
875
875
875
Emergency stop torque
T
2Not
[Nm]
(1000 times possible during
the service life of the gearbox)
–
2300 2300 2300 2300 2300 2300 2200 2300
Permissible average input
speed n
1N
[min
-1
]
(With T
2N
and 20 °C ambient
temperature)
–
2000 2000 2000 2000 2000 2000 2000 2000
Max. input speed n
1Max
[min
-1
]
–
3200 3200 3200 3200 3200 3200 3200 3200
Average no-load running
torque T
012
[Nm]
(For n
1
=3000 min
-1
and
gearbox temperature 20 °C)
a
–
7.0
5.8
5.2
5.2
4.5
4.4
4.5
3.1
Max. backlash j
t
[arcmin]
–
Standard ≤ 3 / Reduced ≤ 1
Technical data for TP
+
110 MF, 1-stage
Clam-
ping
hub Ø
[mm]
Ratio i
4
5
7
8
10