TP
+
ATEX
Appendix
Revision: 04
2022-D020259
en-29
10.4
Specifications for startup and operation
Any mounting position can be selected for this gearbox.
10.4.1 Impermissible operating conditions
The mounting of a shrink disc is
not
intended for this product type.
Ordering code: TP..xxxx-xAx-xxxxx-xxx-xx; HIGH TORQUE
Output flange
Gearbox
size
TP..
Hole
circle Ø
[mm]
Quantity x thread x
screw depth
[ ] x [mm] x [mm]
Tightening torque
[Nm]
Property class 12.9
110
125
12 x M12 x 19
126
Tbl-16: Thread in output flange TP
+
Maximum permitted axial forces
Mounting by pressing or shrink-fitting is
not
intended for this product type.
Tbl-17: Specifications for mounting to the output side
Ambient temperature
Product type
Minimum temperature
[°C]
Maximum temperature
[°C]
TP
+
0
+40
Operating temperature
Product type
Max. permissible housing temperature [°C]
TP
+
+80
Tbl-18: Ambient temperature / Operating temperature
The following operating conditions are not permitted:
- Co-riding the gearbox on the drive axle is prohibited. Exceptions require a written
approval and technical statement from
WITTENSTEIN alpha GmbH
.
- Use in continuous duty (S1 duty: power-on time greater than 60% or longer than
20 minutes)