![Wittenstein Alpha Advanced TP+ 004 Operating Manual Download Page 35](http://html1.mh-extra.com/html/wittenstein-alpha/advanced-tp-004/advanced-tp-004_operating-manual_990177035.webp)
TP
+
ATEX
Appendix
Revision: 04
2022-D020259
en-33
Technical data for TP
+
004, 2-stage, i = 40 – 100
Clam-
ping
hub Ø
[mm]
Ratio i
40
50
61
64
70
91
100
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
38
44
36
28
44
26
28
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
28
28
21
13
28
11
13
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the
service life of the gearbox)
–
85
85
85
55
85
72
72
Permissible average input
speed n
1N
[min
-1
]
(With T
2N
and 20 °C ambient
temperature)
–
3200 3840 4400 4400 4400 4400 4400
Max. input speed n
1Max
[min
-1
]
–
4800 4800 4800 4800 4800 4800 4800
Average no-load running
torque T
012
[Nm]
(For n
1
=3000 min
-1
and gearbox
temperature 20 °C)
a
–
0.18
0.17
0.16
0.17
0.17
0.15
0.16
Max. backlash j
t
[arcmin]
–
Standard ≤ 4 / Reduced ≤ 2
Torsional rigidity C
t21
[Nm/arcmin]
–
11
12
9
12
11
7
8
Max. axial force F
2AMax
[N]
b
–
1304
Max. tilting moment M
2KMax
[Nm]
–
88
Service life L
h
[h]
–
see Chapter 7.2.3 "Replacing the gearbox"
Weight incl. standard adapter
plate m [kg]
–
1.5
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 54
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see Chapter 10.4 "Specifications for startup and
Lubrication
–
High-performance lubricating grease based on
mineral oil