TP
+
ATEX
Appendix
Revision: 04
2022-D020259
en-35
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 57
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see Chapter 10.4 "Specifications for startup and
Lubrication
–
High-performance lubricating grease based on
mineral oil
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
14
0.78
0.62
0.48
0.48
0.40
19
0.95
0.79
0.64
0.64
0.57
24
2.32
2.16
2.02
2.02
1.94
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-23: TP
+
010, 1–stage: Technical data for use in potentially explosive atmospheres
Technical data for TP
+
010, 2-stage, i = 16 – 35
Clam-
ping
hub Ø
[mm]
Ratio i
16
20
21
25
28
31
32
35
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
114
114
80
114
114
88
88
114
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
63
63
56
63
63
49
49
63
Emergency stop torque
T
2Not
[Nm]
(1000 times possible during
the service life of the gearbox)
11
152
190
200
200
200
200
200
200
14 / 19
200
200
200
200
200
200
200
200
Permissible average input
speed n
1N
[min
-1
]
(With T
2N
and 20 °C ambient
temperature)
–
2800 2800 2800 2800 2800 2800 2800 2800
Max. input speed n
1Max
[min
-1
]
–
4800 4800 4800 4800 4800 4800 4800 4800
Average no-load running
torque T
012
[Nm]
(For n
1
=3000 min
-1
and
gearbox temperature 20 °C)
a
–
0.56
0.48
0.47
0.44
0.40
0.40
0.40
0.28
Technical data for TP
+
010, 1-stage
Clam-
ping
hub Ø
[mm]
Ratio i
4
5
7
8
10