Max. axial force F
2AMax
[N]
b
–
1304
Max. tilting moment M
2KMax
[Nm]
–
88
Service life L
h
[h]
–
see Chapter 7.2.3 "Replacing the gearbox"
Weight incl. standard adapter
plate m [kg]
–
1.4
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 55
Max. permissible housing
temperature [°C]
–
+80
Ambient temperature [°C]
–
see Chapter 10.4 "Specifications for startup and
Lubrication
–
High-performance lubricating grease based on
mineral oil
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
11
0.17
0.14
0.11
0.11
0.09
14
0.25
0.21
0.18
0.18
0.17
19
0.57
0.54
0.51
0.51
0.49
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-20: TP
+
004, 1–stage: Technical data for use in potentially explosive atmospheres
Technical data for TP
+
004, 2-stage, i = 16 – 35
Clam-
ping
hub Ø
[mm]
Ratio i
16
20
21
25
28
31
32
35
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
44
44
32
44
44
32
32
44
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
28
28
21
28
28
21
21
28
Emergency stop torque
T
2Not
[Nm]
(1000 times possible during
the service life of the gearbox)
–
85
85
85
85
85
85
85
85
Permissible average input
speed n
1N
[min
-1
]
(With T
2N
and 20 °C ambient
temperature)
–
3200 3200 3200 3200 3200 3200 3200 3200
Technical data for TP
+
004, 1-stage
Clam-
ping
hub Ø
[mm]
Ratio i
4
5
7
8
10