rev02
MRK950-MRK960 Manager
Pag.
19
When the user accesses this tool, the software switch mode automatically to EDIT; disabling
the direct application of the modified parameters. This is done to assure a better control of
the user over the software and to avoid a destructive mis-reprogrammation of the systems.
To save effectively the new configuration to the modified systems, it is necessary to switch
manually to LIVE mode, after a check that all the data copy operations has been done in the
right way.
Source and destination can be selected between system (a physical device connected) and file.
When a file operation is chosen, the software ask the user to browse to a specific file to be
used.
In both system and file operations, on the left of the window are visualized two tree-views,
showing the structure of the system available to copy the data. In the case of a file source, the
tree-view shows the structure relative to the data that was saved in the moment of the file
creation.
Data copy is easy.
Select source and destination of the operation in the two tree-views. Both receivers and
systems can be used as source and destination, with the difference that if a receiver is
selected, the data copy will affect just the selected receiver itself, but if a whole system is
selected, the operation will be related to all the receivers in the selected system.
It is also possible to copy between a receiver on a system and a system itself, allowing the user
to fast mirror the configuration of the selected receiver to all the other.
After the source and destination selection, the group grid is repainted, showing a list of all
available source and destination frequency groups. By default each group is disabled for copy
and the target group is the same as the source group. The user has the ability to change the
destination of frequency program on different groups, using the drop down lists on the central
column of the grid, and to choose which groups must be copied, with the checkbox on the
rightmost column. Beside the frequency data, the user can choose to copy also other receivers
and system data selectively, like Name, Channel, PTT configuration, NR System, and so on...
When all the copy setup is ready, press
GO
.
The routine can be restarted several times to repeat the operation with different parameters,
to achieve special data treatments.