![Wisenet SRB-160S User Manual Download Page 46](http://html.mh-extra.com/html/wisenet/srb-160s/srb-160s_user-manual_989094046.webp)
trouble shooting
46_
trouble shooting
ONE-TOUCH BUTTON SETUP ERROR
•
ONE-TOUCH BUTTON SETUP ERROR
I
Message
Cause & Solution
SYS INIT FAILED
SYS IS OPERATING
`
Cause
The device is operating as an iSCSI storage.
The HDDs secured in the device have prior RAID information.
`
Solution
①
Connect to the web page of the device.
②
Input the password to login.
③
Select the RAID Management category, the subordinate
category of the STORAGE
④
Select the RAID menu on the tab menu.
⑤
The information of HDD secured in the device can be shown.
⑥
Click the [Delete RAID] button. If there are any volume or
iSCSI target on the RAID group, delete the volumes and the
iSCSI targets and try again.
⑦
If the Storage Reset was performed properly, you can see
the below message in the front LCD.
RAID GROUP1
NO INFORMATION