TSW200E1
Then press <F3> (ENTER). The first chosen module screen will then be displayed.
To access the equipment memory, press <F1> (MEMORY). Section 6 of this manual details
the operation of the equipment memory.
3.3 - DTE and DCE Simulation
3.3.1 - DTE Simulation
For the TSW200E1 to simulate a data terminal equipment, it is necessary to connect it to a
DCE (for example a modem). If the DCE under test does not have the CTS and DCD signals in an
active state, it is possible to force their corresponding levels using a cable that connects the CTS,
DCD and RTS signals. If the DCE needs other signals, the user should perform the necessary
connections.
3.3.2 - DCE Simulation
The TSW200E1 can simulate a data communication equipment as described below:
●
V.24/RS232 Interface: the user can use a CROSS cable. The user has only to connect a terminal
to the TSW200E1 and run the desired tests.
●
V.35/V.11, V.36/V.11 and X.21/V.11 Interface: the TSW200E1 can do DCE
simulation with the V.35/V.11, V.36/V.11 and X.21/V.11 interfaces. It can be
done using the CROSS cable (See Appendix C for a description of these
interfaces). The cable must have the pin settings shown on the table below.
The connector pinout assignment for DCE simulation is listed on Appendix F.
Wise Telecommunications Industry
18
Summary of Contents for TSW200E1
Page 1: ...Operation Manual TSW200E1 Version 1 Revision 7 November 2010 ...
Page 2: ......
Page 4: ......
Page 8: ......