TSW200E1
buzzer is active and when OFF, the buzzer is inactive.
•
Loopback
: Allows the equipment to be configured to perform a local loopback test
(LOCAL), remote (REMOTE) or no loop at all (NONE). For the local loopback, the
same data transmitted by the equipment are internally sent to its reception. So, the
equipment can be in sync when the test is started, without receiving external data. For
the remote loopback, the equipment sends the data it is receiving.
BACK MENU
F1 F2 F3 F4
TX/RX FRAMED
Period:
Allocation:
1 day
35.50%
M.2 100
The TSW200E1 calculates parameters following ITU-T Rec. M.2100. The user must preset
these parameters. This configuration establishes the test time for M.2100. The TSW200E1 tests up
to 8 periods. After that, it starts to write over the old tests. That means that at each 8 periods the
TSW200E1 starts a new cycle.
5.3.2 - TX/RX FRAMED Mode test example
The figures below demonstrate two ways of performing the test using this mode.
5.4 - The THROUGH FRAMED Mode
In this mode, the TSW200E1 is inserted in the circuit under test and the received framed
Wise Telecommunications Industry
51
Summary of Contents for TSW200E1
Page 1: ...Operation Manual TSW200E1 Version 1 Revision 7 November 2010 ...
Page 2: ......
Page 4: ......
Page 8: ......