TSW200E1
•
histograms of errors or alarms versus time
•
event log of alarms
4.4.1 - Basic Errors
In the BERT/BLERT module, four screens display the basic errors. Two screens report to
Recommendation G.821. In one of them the counters are displayed and in the other the percentage
of the counters is displayed.
The first basic errors screen is seen next.
MENU NEXT
F1 F2 F3 F4
B A S I C E R R O R S
BIT ERR = 0000000
BER = 0.00E-00
RX RATE = 2048000 bps
TIME =
0000:10:26
MENU NEXT
F1 F2 F3 F4
B A S I C E R R O R S
BIT ERR = 0000000
BER = 0.00E-00
INJEC. ERR. = 0000000
TIM E =
0000:10:26
This screen displays the following test results:
•
BIT ERROR: Counter that indicates the number of errored bits that occurred during the
running test.
•
BER: Exponential notation rate between the number of errored bits and the total number
of received bits.
•
RX RATE: For the asynchronous mode, it indicates the preset programmed rate.
•
INJEC. ERR.: Displays the number of transmission errors inserted by means of the
ERROR key.
•
TIME: Shows the total elapsed test time. Format: hours:minutes:seconds.
From this first basic error screen it is possible to go three ways:
a. Press <F4> (NEXT) to access the second screen
Wise Telecommunications Industry