TReX User Manual v2.14 Firmware
Outputs Menu
1-8
The output to configure. If the output has been configured for general output control through
telemetry or messaging the output must be configured to LATCHED or MSHOT. In order to
set to LATCHED or MSHOT the output mode must be set to
TELEMETRY
in the Output
Config Sub-Menu.
If the output has already been assigned for a special output function, the function will be
displayed against the output e.g. RF ERROR. If the output has been configured to more than
one function, the output setting will display MULTI. The output can be configured to operate
on many actions at once.
Note: Care must be taken when assigning an output to more than one function as the
behaviour of the output can be difficult to predict or determine the trigger for the output
change. In general, assignment of an output to more than one function is not recommended.
© WTE Limited, 2018 – Christchurch New Zealand
Page 59 of 158