TReX User Manual v2.14 Firmware
TX COUNT LOW
If set to 0, then there will there will be NO transmissions when moving to the LOW state. If
non-zero then this is the number of times the LOW message will be transmitted.
If there is a change of state again, then any remaining transmissions are cancelled.
When set to a non-zero TX COUNT, the input level is considered to be ENABLED, and
displayed as ENABLED on the upper menu level.
RETX DELAY LOW
How long in seconds before sending the next message if set to more than 1.
DEBOUNCE LOW
How long in seconds that the input must be settled at a LOW level before transmitting
THRESH LOW
When configuring inputs 1-8, this field has no function.
On the BATT input this is the voltage that the TReX BATT input is considered to be low. A
voltage below this may result in a BATT transmission if configured.
On the ADC 1 and ADC 2 inputs this is the ADC count that the TReX ADC input is considered
to be low. An ADC count below this may result in an ADC input transmission if configured.
MSG LOW
The message that is transmitted (formatted for the selected protocol) when the input moves to
the LOW level. Input messages must always use WT Protocol.
TX COUNT HI
If set to 0, then there will there will be NO transmissions when moving to the HIGH state. If
non-zero then this is the number of times the HIGH message will be transmitted.
If there is a change of state again, then any remaining transmissions are cancelled.
When set to a non-zero TX COUNT, the input level is considered to be ENABLED, and
displayed as ENABLED on the upper menu level.
RETX DELAY HI
How long in seconds before sending the next message if set to more than 1.
DEBOUNCE HI
How long in seconds that the input must be settled at a HIGH level before transmitting
THRESH HI
When configuring inputs 1-8, this field has no function.
On the BATT input this is the voltage that the TReX BATT input is considered to be high. A
voltage above this may result in a BATT transmission if configured.
On the ADC 1 and ADC 2 inputs this is the ADC count that the TReX ADC input is considered
to be HIGH. An ADC count above this may result in an ADC input transmission if configured.
© WTE Limited, 2018 – Christchurch New Zealand
Page 57 of 158