![background image](http://html.mh-extra.com/html/wire-wizard/gas-tracker/gas-tracker_installation-and-operation-manual_988434011.webp)
9
Viewing the Totalizer
▶ Each time an event is recorded the gas consumed is added to the totalized gas amount.
▶ The totalized gas amount can be viewed by clicking the
Totalizer
tab on the left hand
side of the screen.
▶ The totalized page shows the following information:
Last Reset
(Time and Date),
Count
(event count since last reset),
Consumed
(amount of gas consumed since last reset),
and
Average Flow
(Average flow rate since last reset).
Viewing Historical Data
▶ Historical data can be viewed under the
History
page. The
History
page shows the time
and date of each weld. It also shows the
Duration, Average Flow Rate, Peak Flow,
and
Gas Consumed
for each specific weld.
▶ The data can be toggled back and forth using the arrows at the bottom of the page.
Viewing Device Information
▶ The
About
page shows the
Software Version, Build Date, Calibration Date,
and
Serial Number
.
▶ Access this data by clicking the
About
tab on the left hand side of the touch screen.
Editing/Refilling Gas Setup
▶ There are two options to edit the gas settings.
▶ Option 1 is by clicking the gas remaining bar graph on the right hand side of the touch screen.
Option 2 is by clicking the
Setup
tab and then clicking the
Gas Setup
button.
▶ Once in the
Gas Setup
page, the
Gas Type
and
Cylinder Capacity
can be changed if
required. To keep the same
Gas Type
and
Cylinder Capacity
but just do a refill click the
Refill
button. Click
Yes
or
No
accordingly on the pop up and use the back arrow to
reverse out to the
Home
page.
Clearing the Totalizer
▶ The gas
Totalizer
has a clearing function to reset it to zero.
▶ Complete this task by clicking on the
Totalizer
tab and then clicking the
Reset Total
button at the bottom of the page.
▶ The most recent reset time will update to the time the button was pressed. The
Count,
Consumed,
and
Average Flow
will all say 0 until the next time gas flows through the sensor.
▶ All gas used after a clear will be tallied and totaled until another clear is done.
▶ The
Reset Total
button only clears the totalizer and no other data.
Clearing System Data
▶ If all the weld data is to be cleared from the unit it can be done via the
Clear Data
button found on the
About
tab.
▶ The
Clear Data
button clears all previously saved events. The only thing not cleared by
this is the
Alert
and
Output
settings which have been previously configured.