18
GAS TRACKER INSTALLATION & OPERATION MANUAL
Coil
Name
Description
00001 Metric Units
Setting to 1 causes the display to show in Metric units. Setting to 0
causes the display to show in Imperial units. This does not affect data
available in Modbus registers, which are always in Imperial units.
00003 Restart Application Resets the
Gas Tracker
software by triggering the unit to reboot itself.
00021 Store Gas Settings
Persists the updated gas type and cylinder volume.
00022 Refill Gas
Refills the gas remaining to 100% of the cylinder capacity.
00031 Persist Time
Persists the current timestamp to a hardware RTC.
00041 Reset Totalizer
Resets the totalizer to zero consumption.
00101 Clear Data
Commands the unit to erase all weld events in its memory. This also
resets the totalizer and restarts the application.
Discrete
Input
Name
Description
10001
Charging
Indicates that the AC power adapter is connected, and the unit is charging.
10002
Fully Charged
Indicates that the AC power adapter is connected, and the unit has
completed charging.
10003
Heartbeat
Toggles roughly every second to indicate the unit is running.
10011
Gas Flowing
High whenever gas is flowing through the
Gas Tracker
.
10012
High Peak
Flow Warning
Triggered after a weld completes, if the flow exceeded the peak
threshold. Resets with the next weld.
10013
Low Flow Warning Triggered after a weld completes, if the average flow was less than
the threshold. Resets with the next weld.
10014
High Flow Warning Triggered after a weld completes, if the average flow was more the
threshold. Resets with the next weld.
10015
Low Consumption
Warning
Triggered after a weld completes, if the volume of gas consumed
was less than the threshold. Resets with the next weld.
10016
High Consumption
Warning
Triggered after a weld completes, if the volume of gas consumed
was more than the threshold. Resets with the next weld.
10017
Low Cylinder
Warning
Triggers any time the amount of gas remaining in the cylinder is less
than the threshold. Resets when the cylinder is refilled.
Discrete Inputs
Modbus Register Definitions
Coils