Input Register
Name
Description
30001
Identifier
Always equal to 0x31C0. Used a signature to identify this as
a Tracker.
30002
Firmware Version
Firmware version running on the Tracker. 1014 equals 1.014.
30021
Instantaneous
Gas Flow
Gas flow reading in hundredths of cubic feet per hour as a
signed value.
30022
Remaining
Gas Capacity
Gas capacity remaining in hundreds of cubic feet as an
unsigned value.
30031
Last Weld Duration Duration of last weld event in tenths of seconds as an
unsigned value.
30032
Last Weld
Average Flow
Average flow from last weld event in hundredths of cubic
feet per hour as an unsigned value.
30033
Last Weld
Peak Flow
Peak flow from last weld event in hundredths of cubic feet
per hour as an unsigned value.
30071
Totalizer Count
Number of welds in the totalizer as an unsigned value.
30072, 30073
Totalizer Duration
Duration of all welds in the totalizer in tenths of a second.
Occupies two registers, is a 32-bit unsigned value.
30074, 30075
Totalized
Consumption
Gas consumption of all welds in the totalizer in hundredths of
cubic feet. Occupies two registers, is a 32-bit unsigned value.