1. Maintenance. 

  

It should keep dry, clean and well-ventilated around the units to maintain its good effect 
of heat transfer and energy saving.

 

 

  

Check the parts of the unit and the pressure of the system regularly (once 1 year). If 
there is any unusual phenomena, repair and replace it immediately.

 

 

Check if the electrical wiring is not firm enough and the electrical element has any 
unusual action and smell. If so, repair and replace it immediately.

 

 

Do not make the unit power off if the unit is not used for a long time. We will not be

 

responsible for any lost caused by the frost crack of parts due to the long time power off.

 

 

Check if the power socket and plug have a good contacting, perfect earthing and 
thermal protections.

 

 

In the cold area (below 0 °C), if you do not use the unit for a long time, please drain the water 
in the tank to avoid the damage due to freeze.

 

 

  

It is recommended that the set temperature can be set lower when there is enough hot 
water for daily life to saves energy and extend the service life of water heater.

 

 

  

Specification of the fuse in the controller is 5AL250V; meaning: 250V, 5A.

 

 

2. PCB I/O port 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

  

Filter must be cleaned once a half year. Remove 
the filter following  the picture below  and clean  it 
with tap water.

 

 

   

Loosen the two screws in the top of the water

 

heater(indicated in the picture blow) to remove the 
front panel and wire controller.

 

 

Squeeze and pull out the filter.

 

 

Filter

 

 

Loosen  the  2  screws  here 
to  remove  the  front  panel 
and wire controller.

 

 

 

WARNING

 

The heat pump must be installed by qualified personnel to avoid 
improper installation which will lead to water leakage, electrical 
shock or fire.

 

CN3

 

GND

 

AI06 

GND 
AI05 
GND

 

AI04 

GND

 

AI03 

GND

 

AI02 

GND 
AI01

 

CN2

 

AC-N

 

 

 

CN1

 

OUT5

 

HW200

 

OUT3

 

 

OUT4

 

CN4

 

CN19 

CN6

 

OUT2

 

OUT1

 

  

 

4

 

3

 

  

 

4

 

3

 

1

2

V

 

N

E

T

 

G

N

D

 

D

I0

1

 

G

N

D

 

D

I0

2

 

G

N

D

 

D

I0

3

 

G

N

D

 

D

I0

4

 

G

N

D

 

D

I0

5

 

G

N

D

 

D

I0

6

 

G

N

D

 

NO.

 

Symbol

 

The definition of the ports

 

1

 

OUT1

 

Compressor(output)(220-230VAC)

 

2

 

OUT2

 

Heater (output)

220-230VAC

 

3

 

OUT3

 

Four way valve (output)(220-230VAC)

 

4

 

OUT4

 

High speed fan/Source pump (output)

220-230VAC

 

5

 

 

OUT5

 

Low speed fan /Circulate pump/Solar pump/

 

Recovery pump/Cooling(output)(220-230VAC)

 

6

 

AC-N

 

Ground

 

7

 

NET GND 12V

 

Remote controller

 

8

 

DI01 GND

 

Remote ON/OFF

 

9

 

DI02 GND

 

Over heat protection

 

10

 

DI03 GND

 

Low pressure protection

 

11

 

DI04 GND

 

High pressure protection

 

12

 

DI05 GND

 

(SPARE)

 

13

 

DI06 DND

 

Flow swtich protection

 

14

 

AI01 GND

 

Ambient temp. sensor(input)

 

15

 

AI02 GND

 

Tank of bottom temp.Sensor(input)

 

16

 

AI03 GND

 

Tank of top temp. Sensor(input)

 

17

 

AI04 GND

 

Coil temp. Sensor/Anti-freeze Sensor(input)

 

18

 

AI05 GND

 

Suction temp. sensor(input )

 

19

 

AI06 GND

 

Solar temp.sensor(input)

 

20

 

CN6

 

Running indication/Circulate pump/Solar pump

 

 

Summary of Contents for WSW2.5-300 L

Page 1: ...SANITARY WATER RESERVER Installation Operation Manual WARNING The water heater must be used in reliable ground connection...

Page 2: ...carefully before use the unit All safety measures have safety warnings The followings are the meanings of each warning There will be potential danger for you and others Wrong operations may lead to t...

Page 3: ...more than 50 C please have a qualified socket to replace it to avoid the burnout or fire caused by the bad contact In the water splashed places and may be on the wall the installation height of power...

Page 4: ...e risk or serious injure ATTENTION There will be potential danger for you and others Icon Meaning Prohibition What is prohibited will be nearby this icon Compulsory implement The listed action need to...

Page 5: ...ll lead to water leakage electrical shock or fire Choose the place that there are no direct sunlight and other heat radiating If you can not avoid it please install coverings to prevent the direct sun...

Page 6: ...withsimpleoperationbutalsocouldsetthewatertemperatureaccordingtotheambient temperature heating the water meanwhile recycling indoor waste heat Refrigerant is compressed into vapor with high temperatur...

Page 7: ...rating parameters The range of the operating water temperatures 9 70 C The range of the operating water pressures 0 15 0 7MPa Solar water outlet Drainage Water inlet A B C 116 244 800 Model WSW2 5 300...

Page 8: ...erent needs and conditions Solar water inlet Water source 600 500 The unit only can use tap water Please do not use the water from any lake river or underground water which are not filtrated or treate...

Page 9: ...ht of forklift at a lowest level Because the top part is heavier the operator needs to take measures to prevent its overturn To avoid any damages the unit must stand on a flat place Transport for inst...

Page 10: ...hould be clean no rusty spots and dirts to avoid any pipe jam After connecting pipes please check the leakage status of whole system to assure there is no leakage firstly and then make the insulation...

Page 11: ...controller to see if there is any malfunction Trial running Use the wire controller to start the unit When compressor is running hear whether there is strange sound or not If abnormal sound occurs ple...

Page 12: ...It is showed when unit is in auto mode Heating It is showed when unit is in heating mode Vacation mode It is showed when unit is in vacation mode Off peak mode It is showed when unit is in off peak m...

Page 13: ...economic mode for a certain period and run in high requirement mode for the others Automatic heating mode the unit will change its mode according to the ambient temperature Vacation mode the unit wil...

Page 14: ...ss to save setting At the same time month start to flashing press to increase value or press to decrease value and press to save setting At the same time year start to flashing press press to increase...

Page 15: ...n the following Attention If there is no operation for 5s system will remember clock setting and back to the main interface Timer 1 off has been set 2 The timer on off setting operation at vacation mo...

Page 16: ...when the outlet temperature reaches target temperature system will shut down electric heater automatically It is used for high requirement When the unit is off you can start up electric heater only by...

Page 17: ...7 Operation and Usage 7 Operation and Usage 26 27 Set point of target temp 55 C Ajustable...

Page 18: ...ure below and clean it with tap water Loosen the two screws in the top of the water heater indicated in the picture blow to remove the front panel and wire controller Squeeze and pull out the filter F...

Page 19: ...ing mode Answer The unit needs to defrost when the evaporator freezes because of the low ambient temperature The compressor will stop and the fan keeps running when the unit defrosts 8 Why is the heat...

Page 20: ...taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs This product is compliant with directiv...

Reviews: