background image

4.Specs 

 

   4. Specs 

 

8

 

9

 

 

 

model

 

 

4.Dimensions

 

unit

mm

 

5. Performance parameter

 

 
 
 

Model

 

dimension

 

WSW2.5-300 L

 

A

 

1976

 

B

 

1467

 

C

 

1212

 

D

 

Φ640

 

 
 
 
 
 
 
 
 
 
 
 

 

 

Hot water outlet

 

 
 
 

Magnesium

 

P&T Valve

 

 

Overheat protector recovery

 

 
 

 

Measurement conditions:

 

Instant heating: Ambient temperature15°C /13°C,Water inlet 15°C Water outlet 45°C

 

 

 

Solar water inlet

 

Work range

 

 

(1).Ambient temperature is -7°C -43°C (Heat Pump)  

 

(2).The max temperature of water tank is 70°C

 

 

Temp sensor

 

 

Eletricity heater

 

 

Operating parameters

 

The range of the operating water temperatures: 9~70°C

 

The range of the operating water pressures: 0.15~0.7MPa

 

 

Solar water outlet

 

Drainage

 

 

Water inlet

 

A

 

B

 

C

 

116

 

  

  

244 

 

800

 

Model

 

 

WSW2.5-300 L

 

Heating capacity

 

kW

 

3.2

 

Water tank capacity

 

L

 

300

 

Power input

 

kW

 

0.89

 

Running current

 

A

 

4.0

 

Power supply

 

 

230V~/50Hz

 

Compressor Number

 

 

1

 

Compressor

 

 

rotary

 

Rated outlet water Temp.

 

°C

 

55

 

Air volume

 

m

3

/h

 

450

 

Air pressure

 

Pa

 

40

 

Duct diameter

 

mm

 

Φ150

 

Nosie

 

dB(A)

 

45

 

Water inlet/outlet size

 

inch

 

3/4

 

*Auxiliary E-heater

 

kW

 

1.5

 

Net dimensions

 

mm

 

See the drawing of the units

 

Shipping dimensions

 

mm

 

See package label

 

Net weight

 

kg

 

125

 

Shipping weight

 

kg

 

145

 

 

Summary of Contents for WSW2.5-300 L

Page 1: ...SANITARY WATER RESERVER Installation Operation Manual WARNING The water heater must be used in reliable ground connection...

Page 2: ...carefully before use the unit All safety measures have safety warnings The followings are the meanings of each warning There will be potential danger for you and others Wrong operations may lead to t...

Page 3: ...more than 50 C please have a qualified socket to replace it to avoid the burnout or fire caused by the bad contact In the water splashed places and may be on the wall the installation height of power...

Page 4: ...e risk or serious injure ATTENTION There will be potential danger for you and others Icon Meaning Prohibition What is prohibited will be nearby this icon Compulsory implement The listed action need to...

Page 5: ...ll lead to water leakage electrical shock or fire Choose the place that there are no direct sunlight and other heat radiating If you can not avoid it please install coverings to prevent the direct sun...

Page 6: ...withsimpleoperationbutalsocouldsetthewatertemperatureaccordingtotheambient temperature heating the water meanwhile recycling indoor waste heat Refrigerant is compressed into vapor with high temperatur...

Page 7: ...rating parameters The range of the operating water temperatures 9 70 C The range of the operating water pressures 0 15 0 7MPa Solar water outlet Drainage Water inlet A B C 116 244 800 Model WSW2 5 300...

Page 8: ...erent needs and conditions Solar water inlet Water source 600 500 The unit only can use tap water Please do not use the water from any lake river or underground water which are not filtrated or treate...

Page 9: ...ht of forklift at a lowest level Because the top part is heavier the operator needs to take measures to prevent its overturn To avoid any damages the unit must stand on a flat place Transport for inst...

Page 10: ...hould be clean no rusty spots and dirts to avoid any pipe jam After connecting pipes please check the leakage status of whole system to assure there is no leakage firstly and then make the insulation...

Page 11: ...controller to see if there is any malfunction Trial running Use the wire controller to start the unit When compressor is running hear whether there is strange sound or not If abnormal sound occurs ple...

Page 12: ...It is showed when unit is in auto mode Heating It is showed when unit is in heating mode Vacation mode It is showed when unit is in vacation mode Off peak mode It is showed when unit is in off peak m...

Page 13: ...economic mode for a certain period and run in high requirement mode for the others Automatic heating mode the unit will change its mode according to the ambient temperature Vacation mode the unit wil...

Page 14: ...ss to save setting At the same time month start to flashing press to increase value or press to decrease value and press to save setting At the same time year start to flashing press press to increase...

Page 15: ...n the following Attention If there is no operation for 5s system will remember clock setting and back to the main interface Timer 1 off has been set 2 The timer on off setting operation at vacation mo...

Page 16: ...when the outlet temperature reaches target temperature system will shut down electric heater automatically It is used for high requirement When the unit is off you can start up electric heater only by...

Page 17: ...7 Operation and Usage 7 Operation and Usage 26 27 Set point of target temp 55 C Ajustable...

Page 18: ...ure below and clean it with tap water Loosen the two screws in the top of the water heater indicated in the picture blow to remove the front panel and wire controller Squeeze and pull out the filter F...

Page 19: ...ing mode Answer The unit needs to defrost when the evaporator freezes because of the low ambient temperature The compressor will stop and the fan keeps running when the unit defrosts 8 Why is the heat...

Page 20: ...taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs This product is compliant with directiv...

Reviews: