6. Installation and Connecting Pipe
6. Installation and Connecting Pipe
12
13
2. Choose the suitable unit
In order to save the energy, please choose the suitable unit.
People
Recommended models
6
~
7people
300L
Attention: The above is just for reference, please choose the unit according to
local environment and actual usage habits.
3. Storage and transportation
Generally, it's better to use a container to transport hot water heat pumps and store them in a
suitable and dry place. To short distance carrying, please be careful and the maximum inclination is
no more than 60° .During transportation and storage, the ambient temp is better from -10°C
—+43°C
Transported by forklift
When using forklift to carry the unit which must have a pallet, the operator should try best to keep
the height of forklift at a lowest level. Because the top part is heavier ,the operator needs to take
measures to prevent its overturn. To avoid any damages, the unit must stand on a flat place.
Transport for installation
When transporting for installation, the bottom of unit needs to be added with pallet and use a rope
or belt to fix it well. By this manual carrying or forklift transportation, the inclination is no more than 60
as the following picture shows. If the inclination unavoidably exceeds 60°, the unit must be kept at
vertical status for at least 1 hour and then can be started for testing or running.
4 Installation position
(1) Waste heat is useful heat
The standard hear exchanger of the hot-water heat pump enables direct connection to a
second heat generator, e.g. a solar heating system or a boiler.
(2) Dehumidification in the recirculating air mode
Dehumidified air in the laundry room supports laundry drying and prevents moisture-
induced damage.
Attention
:
Avoid overturning.