background image

2.Choice of installation site 

 

  3.Safety caution 

 

2

 

3

 

 

 

 

Choice of the installation site of the unit

 

1

 

The water heater can be installed indoors or outdoors. Recommend the installation in the 

balcony. If installed outdoors, please make the rain proof measures.

 

2

 

Choose the place that there are no direct sunlight and other heat radiating. If you can not

 

avoid it, please install coverings to prevent the direct sunlight.

 

3

 

When the air inlet and outlet are not connected to the duct, please make sure no barriers

 

near it. Air outlet could be connected to the air duct to bring fresh cool air into the rooms. If this

 

measure  is  carried  out,  a  reversing  valve  should  be  installed  in  the  air  duct  to  make  the  cool  air 
blows to outdoors in winter. The air inlet could be connected the rooms with the air duct to draft the 
air from and keep fresh air in the rooms.

 

4

 

Provide the sufficient space which is dry and drafty for installation and maintenance.

 

5

 

The supporting surface should be flat(horizontal angle

2 ), and it could withstand the 

weight of water heater. The unit should be installed vertically, and will not cause much noise

 

and vibration.

 

6

 

Operating noise and elimination air could not affect neighbors. 

 

7

 

The place without the combustible gas.

 

8

 

The place convenient for pipe connection and electrical wiring.

 

9

 

There must be electrical insulation between the unit and location site if the site is with a

 

metal part, and such electrical insulation must meet the requirements of the relevant electrical

 

standards.

 

 

To prevent the users and others from the harm of this unit, avoid damage on the unit or other 

property, and use the heat pump properly, please read this manual carefully and

 

understand the following information correctly.

 

 

Mark

 

Meaning

 

 

 

WARNING

 

Wrong operations may lead to the life risk or serious injure.

 

 
 

ATTENTION

 

There will be potential danger for you and others.

 

 

Icon

 

Meaning

 

 

 

Prohibition. What is prohibited will be nearby this icon

 

 

 

 

Compulsory implement. The listed action need to be taken.

 

 

ATTENTION 

(include 

WARNING

)

 

Please pay attention to what is indicated.

 

 

1) The injury means no need to be in hospital and cure for a long time.

 

2) The material lost means property and data lost.

 

 

 

 

 

 

Warning

 

ATTENTION

 

Safety Precautions

 

The following installation site would lead to machine malfunction(Prior 
consultation is necessary if the following site is unavoidable.)

 

The place in which the air is filled with mineral oil;

 

The place in which the air is in high salinity, like seaside;

 

The place in which the air is filled with corrosive gas, like hot spring areas; The 
place with serious voltage fluctuation , like factory;

 

The place inside a car or a cabin;

 

The place in which the air is filled with oil, like kitchen; The 
place with strong electromagnetic wave;

 

The place in which the air is filled with inflammable gas/material; The 
place in which the air is filled with acidity or alkalinity gas;

 

Other special places just like the above.

 

Ins

tall

ation

 

 

 

Professional installer 
is required.

 

The heat pump must be installed by qualified personnel.

 

Improper installation will lead to water leakage, electrical 
shock or fire.

 

 

Earthing is required

 

Please make sure that the unit and power connection are 
with good earthing, or it may cause electrical

 

shock.

 

 

 

Leakage 
Limitation

 

When the unit is installed in a closed room, there should be some 

arrangement to prevent the refrigerant leakage passing the limit value 

and lead to difficult breathing. Please consult the dealer for the

 

arrangement details.

 

 

Ope

ratio

n

 

 

 

PROHIBITION

 

 

DO NOT put fingers or others into the fans and evaporator of 
the unit, otherwise harm may be occurred.

 

 

 

 

Shut off the power

 

 

When there is something wrong or strange smell, the power 
supply should be shut off to stop the unit. Continue to run

 

may cause electrical shock or fire.

 

 

Summary of Contents for WSW2.5-300 L

Page 1: ...SANITARY WATER RESERVER Installation Operation Manual WARNING The water heater must be used in reliable ground connection...

Page 2: ...carefully before use the unit All safety measures have safety warnings The followings are the meanings of each warning There will be potential danger for you and others Wrong operations may lead to t...

Page 3: ...more than 50 C please have a qualified socket to replace it to avoid the burnout or fire caused by the bad contact In the water splashed places and may be on the wall the installation height of power...

Page 4: ...e risk or serious injure ATTENTION There will be potential danger for you and others Icon Meaning Prohibition What is prohibited will be nearby this icon Compulsory implement The listed action need to...

Page 5: ...ll lead to water leakage electrical shock or fire Choose the place that there are no direct sunlight and other heat radiating If you can not avoid it please install coverings to prevent the direct sun...

Page 6: ...withsimpleoperationbutalsocouldsetthewatertemperatureaccordingtotheambient temperature heating the water meanwhile recycling indoor waste heat Refrigerant is compressed into vapor with high temperatur...

Page 7: ...rating parameters The range of the operating water temperatures 9 70 C The range of the operating water pressures 0 15 0 7MPa Solar water outlet Drainage Water inlet A B C 116 244 800 Model WSW2 5 300...

Page 8: ...erent needs and conditions Solar water inlet Water source 600 500 The unit only can use tap water Please do not use the water from any lake river or underground water which are not filtrated or treate...

Page 9: ...ht of forklift at a lowest level Because the top part is heavier the operator needs to take measures to prevent its overturn To avoid any damages the unit must stand on a flat place Transport for inst...

Page 10: ...hould be clean no rusty spots and dirts to avoid any pipe jam After connecting pipes please check the leakage status of whole system to assure there is no leakage firstly and then make the insulation...

Page 11: ...controller to see if there is any malfunction Trial running Use the wire controller to start the unit When compressor is running hear whether there is strange sound or not If abnormal sound occurs ple...

Page 12: ...It is showed when unit is in auto mode Heating It is showed when unit is in heating mode Vacation mode It is showed when unit is in vacation mode Off peak mode It is showed when unit is in off peak m...

Page 13: ...economic mode for a certain period and run in high requirement mode for the others Automatic heating mode the unit will change its mode according to the ambient temperature Vacation mode the unit wil...

Page 14: ...ss to save setting At the same time month start to flashing press to increase value or press to decrease value and press to save setting At the same time year start to flashing press press to increase...

Page 15: ...n the following Attention If there is no operation for 5s system will remember clock setting and back to the main interface Timer 1 off has been set 2 The timer on off setting operation at vacation mo...

Page 16: ...when the outlet temperature reaches target temperature system will shut down electric heater automatically It is used for high requirement When the unit is off you can start up electric heater only by...

Page 17: ...7 Operation and Usage 7 Operation and Usage 26 27 Set point of target temp 55 C Ajustable...

Page 18: ...ure below and clean it with tap water Loosen the two screws in the top of the water heater indicated in the picture blow to remove the front panel and wire controller Squeeze and pull out the filter F...

Page 19: ...ing mode Answer The unit needs to defrost when the evaporator freezes because of the low ambient temperature The compressor will stop and the fan keeps running when the unit defrosts 8 Why is the heat...

Page 20: ...taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs This product is compliant with directiv...

Reviews: