23
3.
Care, Cleaning, and Maintenance
3.3.3.2 Blower box, blower wheel
Attention!
De-energise the boiler before cleaning the blower box and blower wheel! Disconnect power plug
– F
ig. 33.
Recommended cleaning implement: Spatula, brush, and vacuum cleaner
– Disconnect the blower plug – Fig. 33.
– Remove wing nut from blower box – Fig. 34.
– Remove the blower unit and clean blower wheel – Fig. 35.
– Thoroughly clean the blower box interior – Fig. 36.
3.3.3.3 Exhaust pipe:
Recommended cleaning implement: Spatula, cleaning brush, soft cloth
– Clean the exhaust pipe leading to the flue through the cleaning opening provided in the exhaust pipe, or
through the blower box.
– Use soft cloth to clean exhaust sensor (accessory).
Information!
Be careful of the sensors in the flue outlet when cleaning the exhaust pipe - do not bend or damage
them. No warranty claims will be accepted for damage resulting from incorrect cleaning!
Fig. 33 Disconnecting plugs
Power plug
Fig. 34 Disconnect the blower plug and
Remove wing nut
Fig. 35 Cleaning blower wheel
Fig. 36 Clean the interior of the blower box