18
2.
Operation
2.6.4 Replenishing fuel – continuing heating operation
Attention!
Open the filling door carefully (due to the risk of deflagration).
1.) During each fill, press the lever for cleaning heating surfaces around 5–10 times.
2.)
Open the filling door until the stop is against the catch. Wait at least 15 seconds
to allow low temperature
carburisation gases to be sucked away. Lift the hook catch, and completely open the filling door.
3.)
Embers check:
we recommend only replenishing fuel once the wood has already burnt down.
– if sufficient embers remain, spread them evenly throughout the filling chamber and
replenish the fuel as
required
.
– if few or no embers remain, the system must be ignited again – see section 2.6.1.
4.) Close filling door and cladding door.
2.6.5 Wood gasification boiler - end of burning
When combustion ends, the blower continues running until the combustion chamber has cooled down, in order
to best use the remaining embers (depending on the selected burnout mode). Afterwards, it turns off (standby
operating phase).