2.0. Assembly
2.4.3. Electric connection to battery
CAUTION DANGER:
Risk of short-circuit and injury when working on the battery
and electrical system! Electrical current flowing through the
body can cause cramps, ventricular fibrillation, heart stoppage
and internal burns. Risk of burns due to arcing caused by short
circuits
.
•
Protect the battery against damage and moisture.
•
Disconnect the electrical power supply before starting work on
the battery and electrical system.
•
Use suitable tools so as to avoid short circuits.
•
Sure that the cables are routed without tension, kinking and
chafing, and also avoid bending them around sharp edges.
•
During all work on the battery, please comply with the
regulations of the vehicle manufacturer in question.
•
Only use original cables, or ones approved by the manufacturer.
•
Always push on the cap and lock it to protect electrical
connections against damage.jalk
.
Advice
Faulty cables or cables with incorrect dimensions can lead to malfunctions and damage to the
spread- er. Any changes to cable or plug connections without factory approval automatically
invalidates the entire warranty
.
Changes to cables undertaken by the customer are taken into account in the
case of repair. Only use original ca- bles, or ones approved by the
manufacturer. You must consult with the manufacture before carrying out any
cable modifications. Power loss must be taken into account when extending
cables. A poor power supply may prevent you from achieving the desired blower
speed. Also, this could lead to intermittent complete failure.
Technical data, electrical system
Operating voltage
12.5 to 15 V
Fuse
40 A
Speed range
20 to 120 rpm
Power consumption of motor
10 A
Total Power consumption of
Vento
®
II 8-Row
33 A
Total Power consumption of
Vento
®
II 16-Row
45 A
Operating temperature
-10 to +50 °C
Storage temperature
-10 to +50 °C
Battery cable
minimum 6 mm²