Kunststoffschweißtechnik
Diagnosis Program
Chapter 6
19.09.11
Working Instructions WIDOS 5500 CNC 3.0
Page 44 of 78
No.
Signification
0018
- The required joining pressure which was calculated by the programmed
welding parameters is displayed
0021
-
The operation and printout language can be choosen
•
0000 German
•
0001 English
•
0003 French
•
0004 Spanish
0023
-
The automatic change to summer or winter time may be switched on
or off
•
0000 change summer / winter time switched off
•
0001 change summer / winter time switched on
0030
-
All stored weldings are deleted:
•
By entering of 0001 all weldings stored in the RAM memory up to that time
are deleted
•
By reapeted entering of 0001 all weldings stored in the SD–card memory up
to that time are deleted.
0034
-
Bit values from 0-1023 appear which will change together with the change
of the corresponding analog values
•
0005 Travel
•
0008 Heating element temperature PT 1000
•
0010 Environmental temperature
•
0011 Pressure (4-20 mA)
0044
-
A self-test of the machine and the control unit is performed.
Press button <-> for complete the dignosis program