Kunststoffschweißtechnik
Equipment care/Maintenance/Repair
Chapter 7
19.09.11
Working Instructions WIDOS 5500 CNC 3.0
Page 48 of 78
7.8. Error signals
If during the work with the machine
•
the DVS prescriptions are not followed
•
the necessary steps for the welding process are not correctly or not at all performed
•
certain measuring devices do not function
an error message will appear on the display.
By pressing the button <Enter>, the error message can be deleted on the display.
Error Message
Cause
Remedial Action
heating element
temperature not o.k. !
Heating element did not yet
reach the nominal temperature
and is out of the tolerance of ±
10° C
Wait until the heating element is
heated up and the setting
process is finished
pipes clamped
too long !!
Pipes are clamped too close
one to the other and the planer
does not fit between the pipe
ends
Clamp the pipes with more
distance one to the other
insert
heating element !!
Message "insert heating
element" has been confirmed
with <Start> although the
heating element has not yet
been inserted
Insert heating element and
confirm with <Start>
pipes slipped
in clamps
Pipes were not properly
clamped and are slipping
through the clamping devices
Clamp the pipes tightly
heating element
is still inserted !!
After completion of the change
over time, the heating element
was not removed
Abort the welding process and
restart welding
error SD-card
Any other SD-card error
Check if SD-card is present or is
inserted in a wrong way
error SD-card
card full
Memory space of the SD-card
is full
Read data out from the SD-card
and perform new formatting
error SD-card
write protect
SD-card has a write protection
Remove the write protection at
the SD-card
error SD-card
not formatted
SD-card is not formatted and
no data can be stored
Format SD-card with PC
necessarily
using „
FAT16
“
power failure
at last welding
Power supply of the control unit
has been interrupted during the
welding process
Eliminate the cause of the power
failure and restart welding
no welding in
memory
Internal memory is empty
memory full !
Internal memory is full (more
than 400 weldings stored)
Copy internal memory onto SD-
card and then delete it