Kunststoffschweißtechnik
WIDOS
Einsteinstr. 5
Phone +49 (0) 71 52 99 39 - 0
W. Dommer Söhne GmbH D-71254 Ditzingen-Heimerdingen
Fax
+49 (0) 71 52 99 39 - 40
Website: http://www.widos.de
Email: [email protected]
19.09.11
Working Instructions WIDOS 5500 CNC 3.0
Page 43 of 78
6. Diagnosis program
The purpose of the diagnosis program is the modification of stored machine parameters.
In the following lines all important diagnosis numbers for the function tests are described.
Unappropriated operation of the diagnosis functions may lead to disturbances
in the machine and may destroy components.
The diagnosis functions allow a direct access to the specific parameters of the
machine and have to be operated only by skilled staff.
Display:
2
nd
line:
WIDOS 5500 CNC
22.11.2000 10:10
Press button <Enter>
Display:
2
nd
line:
copy
_
Press button <Start> for the next menu
Display:
2
nd
line:
Diag Clk WICON Param
_
10:10
The respective diagnosis number can be set with buttons <+>,
<-> and <Enter>.
No.
Signification
0008
- The actual position of the sledge is displayed
0010
- The actual temperature (°C) of the heating element is displayed
0011
- The environmental temperature (°C) is displayed
0012
- The actual pressure (bar) is displayed
0013
- The required bead height (in 1/10 mm) which was calculated by the
programmed welding parameters is displayed
0014
- The required heating time which was calculated by the programmed
welding parameters is displayed
0015
- The required change over time which was calculated by the programmed
welding parameters is displayed
0016
- The required pressure build-up time which was calculated by the
programmed welding parameters is displayed
0017
- The required cooling time which was calculated by the programmed
welding parameters is displayed