User Manual – Network Video Recorder
168
A HDD can be set to read-only to prevent important recorded files from being overwritten when
the HDD becomes full in overwrite recording mode.
When the HDD property is set to redundancy, the video can be recorded both onto the
redundancy HDD and the R/W HDD simultaneously so as to ensure high security and reliability of
video data.
Step 1
Enter the HDD Information interface.
Menu > HDD> General
Step 2
Select HDD from the list and click the
icon to enter the Local HDD Settings interface.
Set HDD Property
Step 3
Set the HDD property to R/W, Read-only or Redundancy.
Step 4
Click the
OK
button to save the settings and exit the interface.
Step 5
In the HDD Information menu, the HDD property will be displayed in the list.
At least 2 hard disks must be installed on your NVR when you want to set a HDD to Redundancy,
and there is one HDD with R/W property.
12.4 Configuring Quota Mode
Purpose:
Each camera can be configured with allocated quota for the storage of recorded files or captured
pictures.
Step 1
Enter the Storage Mode interface.
Menu > HDD > Advanced
Step 2
Set the
Mode
to Quota.