www.whisperkool.com | Page 5
CEILING MOUNT SPECIFICATIONS
Model
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air Cooled Condensing Unit)
Cellar Size (cu. ft.)
2000
Dimensions
35.75”L x 14.5”W x 12.75”H
17.5”L x 13”W x 13.5”H
BTUh with 90° air entering
the Condenser Coil
4450
CFM
321
350
Refrigerant
R-134a
Condensing Unit HP
1/2
Voltage Rating
(20 amp
dedicated circuit required)
115V or 230V
Weight (lbs)
80
69
AMPS
(Starting/Running)
1.1
48/9.5
dBA
58.5
65
Drain Line
1/4” Condensate
Installation
Evaporator unit (fan coil unit) is installed through the cellar ceiling, condenser is installed up to
100 line ft. from the evaporator unit.
Thermostat
Digital Control Display
Temp. Delta
55°F
max. temperature differential between the cellar temperature and condenser air intake temperature.
Warranty
2-year parts and labor