R
66
4. Remove the appropriate fuse and check if it has blown. The fuses are located at the bottom of
the electronics enclosure and are marked with their current ratings in Ampere. Error codes
displayed on the control panel help identify which circuit and therefore which fuse may
possibly have blown.
5. Replace the faulty fuse.
6. Replace the electronics enclosure cover and fasten the four screws.
7. Replace the enclosure lid.
8. Reconnect the WhisperGen to the battery bank by closing the circuit breaker.
WhisperGen fuses can be obtained from electrical hardware suppliers or your authorised
WhisperGen service agent.
Current Rating
in Ampere
External / Auxillary
Seawater Pump &
Coolant Pump Circuits
Internal Coolant Pump
Circuit
Fuel Pump & Fuel
Shut-off Valve Circuits
Air Blower, Oxygen Sensor,
& Flushing Circuits
Control Panel &
Microcomputer Circuits
Glow Plug Circuit
WTL0038
32A
15
3
5
10
3
Ensure that the replacement fuse is of a similar type and of the correct
current rating.
It is advisable to keep spare fuses with the WhisperGen at all times.