R
24
6. Press
∧
or
∨
to select the maximum number of operating hours for the WhisperGen. If
25
(hours) is selected, the WhisperGen will run continuously until the battery bank is fully
charged.
7. Optional: press
<
repeatedly to return to the default display. You can also let the default
display re-appear automatically by allowing a few minutes of inactivity on the control panel.
If the
Max Run Hours
setting is less than
25
, the WhisperGen will automatically stop when the
Max Run Hours
set value is reached, even if the battery bank is not yet fully charged. If the
Max
Run Hours
setting is left at its default value of
25
, no maximum operating time condition is
imposed: the WhisperGen will run continuously until the battery bank is fully charged.
Note that the
Max Run Hours
setting applies only if the WhisperGen is started manually or from a
remote switch. It does not apply if the WhisperGen automatically starts by itself as a result of the
auto-charge or heat manage function. For more information on battery bank auto-charging, see
section Managing the Battery Bank.
For a summary on operating options, see section Quick Reference - Operating Options.
R
FAULT
AUTOCHARGE
EXT CONTROL
HEAT MANAGE
STOPPING
RUNNING
STARTING
STANDBY
STOP
START
WTL0006
Max Run Hours 21