Troubleshooting
“Built-In” Test Operations and Codes Summery
TYPE OF TEST
CORE BOARD OPERATION)
CHECKING
CODE
NOTE
(USER INTERFACE OPERATION)
Check evaporator de-frost heater
07
Displayed on 2 digit Freezer display
Check fridge probe
06
Displayed on 2 digit Freezer display
Check freezer probe
05
Displayed on 2 digit Freezer display
Check evaporator fan
04
Displayed on 2 digit Freezer display
Check compressor fan
03
Displayed on 2 digit Freezer display
Check damper/air baffle and relay
K008
02
Displayed on 2 digit Freezer display alternatively to the
code “00“
Check water valve
01
Displayed on 2 digit Freezer display alternatively to the
code “00“
Check Ice valve
09
Displayed on 2 digit Freezer display alternatively to the
code “00
Ice-Maker Sankyo initialization
without Ice-Valve activation
12
Displayed on 2 digit Freezer display alternatively to the
code “00“
Default thermostatic operation
00
Displayed on 2 digit Freezer display
Summary of Contents for WSE 2930 W
Page 14: ...Range 2012 Novelties 1 New IDI In Door Ice Sankyo ice maker ...
Page 45: ...Functional characteristics NTC senor in the freezer compartment ...
Page 86: ...Troubleshooting Documents Service Info WSF 7656 W 8586 462 79100 Whirlpool version ...
Page 89: ...Technical Data Main Board ...
Page 92: ...Technical Data Stepper Motor Dispenser assy ...
Page 93: ...Technical Data Dispenser paddle Switch TS 12M AHM B RS Rating 12V DC 50mA ...
Page 94: ...Technical Data Dispenser LED Supply voltage nominal 14 V DC 5 ...