Functional characteristics
Damper control
An electrical AC motor is used to close and open the air door. The motor when supplied rounds always in the
same direction. By means of a cam the air door is driven alternatively in open and close position. A signal is
returned to feedback the position of the air door.
The feedback is generated by means of a switch. During the motor running, when the air door reaches the
close position the switch contacts go from close to open status (no feedback at all).
The switch contacts go from open to close status when the air door is completely opened (220Vac Line
feedback).
The control shall detect the voltage rising and falling edge feedback.
The rising edge indicates the air door is completely opened. The falling edge indicates the air door is
completely closed. If control doesn‟t detect any feedback after 90 seconds from the motor damper
activation, the damper alarm will be set, the alarm will be showed only for 10 minutes since power up.
Note: At every power-up a 25 minutes timer will be set in order to perform a complete damper cycle, to avoid
that the sliding part of the damper will be blocked by ice formation (to guarantee a proper work).
4: Baffle Door
Position
Feedback
5: Motor
Control Output
6: To Neutral
M
o
to
r
4
5
6
Summary of Contents for WSE 2930 W
Page 14: ...Range 2012 Novelties 1 New IDI In Door Ice Sankyo ice maker ...
Page 45: ...Functional characteristics NTC senor in the freezer compartment ...
Page 86: ...Troubleshooting Documents Service Info WSF 7656 W 8586 462 79100 Whirlpool version ...
Page 89: ...Technical Data Main Board ...
Page 92: ...Technical Data Stepper Motor Dispenser assy ...
Page 93: ...Technical Data Dispenser paddle Switch TS 12M AHM B RS Rating 12V DC 50mA ...
Page 94: ...Technical Data Dispenser LED Supply voltage nominal 14 V DC 5 ...