Evaporator Defrost Cycle
Termination of the evaporator defrost cycle :
1.
Standard function switches OFF
2.
Freezer over temperature alarm is OFF
3.
Compressor and both fans(comp evaporator) switches OFF
4.
The air-baffle/damper switches into the CLOSE position
5.
The heater starts to heat the evaporator with the following timing :
6.
The evaporator bimetal thermostat reaches the opening tempe7°C
C)
5 minutes ON
1 minute OFF
3 minutes ON
1 minute OFF
and so on until point 6. takes effect
R-134a
Functional characteristics