Board failure code description
Troubleshooting
CODE
TYPE
DESCRIPTION
UU
Compatibility failure
User Interface board does not recognize the code sent by Main
Control board.
LF
Board failure
User Interface Board did not pass the factory test.
Between both boards (Main Board and User Interface) there will be performed a
compatibility check (communication between the boards). If the Main Board receive a not
recognized code (not specified code), the freezer compartments display show the listed
failure code and no other operations will be accepted, because in case of failure all the loads
will be turned OFF.
Summary of Contents for WSE 2930 W
Page 14: ...Range 2012 Novelties 1 New IDI In Door Ice Sankyo ice maker ...
Page 45: ...Functional characteristics NTC senor in the freezer compartment ...
Page 86: ...Troubleshooting Documents Service Info WSF 7656 W 8586 462 79100 Whirlpool version ...
Page 89: ...Technical Data Main Board ...
Page 92: ...Technical Data Stepper Motor Dispenser assy ...
Page 93: ...Technical Data Dispenser paddle Switch TS 12M AHM B RS Rating 12V DC 50mA ...
Page 94: ...Technical Data Dispenser LED Supply voltage nominal 14 V DC 5 ...