FEATURE BOARD
Refer to page 4-17 for the procedure for servic-
ing the feature board.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch one of the ohmmeter leads to the
wire connector at pin 1 and the other lead
to the wire connector at pin 4 of connector
P2301. The meter should indicate a closed
circuit (0
Ω
).
4.
Touch one of the ohmmeter leads to the
wire connector at pin 2 and the other lead
to the wire connector at pin 3 of connector
P2301. The meter should indicate an open
circuit (infinite).
P2300
P2301
K2003
K2000
1
2
3
4
x
6
1
2
3
4
2
4
3
2
4
3
FUSE 3AB SLO-BLO 12A/250V AX
Refer to page 4-2 for the procedure for servic-
ing a thermal cutoff.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
For the thermal cutoff (N.O.) with the
narrow (3/16
″
) terminals
, touch the ohm-
meter test leads to the terminals. The
meter should indicate an open circuit (in-
finite).
4.
For the thermal cutoff (N.C.) with the
wide (1/4
″
) terminals
, touch the ohmme-
ter test leads to the terminals. The meter
should indicate continuity (0
Ω
).
THERMAL CUTOFF
Thermal Cutoff With
3/16
″
Terminals
Opens @ 70
°
C (158
°
F)
Closes @ 60
°
C (140
°
F)
Thermal Cutoff With
1/4
″
Terminals
Opens @ 96
°
C (205
°
F)
Closes @ 74
°
C (165
°
F)
P2301 - Pin 1
Summary of Contents for Polara GR556LRK
Page 12: ...1 8 NOTES ...
Page 20: ...2 8 NOTES ...
Page 24: ...3 4 NOTES ...
Page 72: ...5 12 NOTES ...
Page 76: ...6 4 NOTES ...
Page 78: ...7 2 STRIP CIRCUITS CONTROL PANEL CLOCK ON CONTROL PANEL COOLING FAN MOTOR OVEN LIGHT BROIL ...
Page 79: ...7 3 BAKE CONVECTION BAKE ACCUSIMMER ...
Page 85: ...8 5 NOTES ...
Page 86: ...8 6 NOTES ...
Page 88: ...CORPORATION ...