5-7
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-15 for the procedure for servic-
ing the convection fan motor.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch one of the ohmmeter leads to the
convection fan motor terminals. The meter
should indicate between 9 and 13
Ω
.
CONVECTION FAN MOTOR
Refer to page 4-30 for the procedure for servic-
ing the evaporator & condenser fan motor.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch one of the ohmmeter leads to pins
1 and 3 of the power connector. The meter
should indicate between 15 and 35
Ω
.
EVAPORATOR & CONDENSER
FAN MOTOR
Power Connector