4-17
REMOVING THE FEATURE BOARD, THE POWER
SUPPLY BOARD, AND THE INLINE FUSE
NOTE:
Sharp edges may be present.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Remove the right side panel from the
refrigerated range (see steps 4a through
4e on page 4-11 for the procedure).
3.
To remove the feature board:
a) Disconnect the wire connectors at
P2300 and P2301.
b) Remove the mounting screw, and slide
the board to the left to unhook it from
the locking tabs.
Power Supply Board
Screw P2 P1 Screw
P2300 P2301 Screw
Feature Board
4.
To remove the power supply board:
a) Disconnect the wire connectors at P1
and P2.
b) Remove the two mounting screws.
5.
To remove the inline fuse
, unlatch the
connector catches from the tabs, and pull
out on the inline fuse connector.
(Viewed From Right Side Of Unit)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Power Supply Board
Feature Board Inline Fuse
Inline Fuse Connector
Connector
Catch Tab